Full Transcript

·YouTLDR

Lecture 01: Magnetic Circuit and Transformer

33:02EnglishTranscribed Jul 20, 2026
0:15

Welcome to this course on Electrical Machines - I, where we will discuss about transformers

0:23

and DC machines. These are the two major topics. And we will begin withtransformers.

0:30

Transformersas we will see will generally consist of a magnetic core material made of

0:42

subtitle, over which there will be at least two coils wound. Andone of the coil will be

0:54

energized withAC source of known frequency and in the other coil will getvoltage of same

1:05

frequency, but at different levels. So, that is primarily the job of a transformer is,

1:14

that is suppose you have a 200 volt 50 hertz supply, you require 400 volt 50 hertz supply,

1:22

then I will use a transformer to change the level of the voltage from 200 to 400 volt

1:31

keeping the frequency constant. It can be similarly a step down situation

1:38

where you have a say 400 volt you want to step it down to 100 volt level then use a

1:48

transformer. Transformer is a static device its efficiency is very large. In case of power

1:56

transformer efficiency could be as large as 99 percent unlike a rotating machine efficiency

2:03

which may be 80 percent, 85 percent very good efficiency because there is no rotating parts

2:10

in it. There will be of course, losses which accounts

2:14

for that 1 percent or 2 percent loss in power, that is there because of conductors will carry

2:23

current it will have a high square or loss. And also core we will see when it is having

2:31

a time varying flux then alsothere will be heat loss inside the core of the material.

2:42

Anyway, those things we will discuss in detail. But it looks like then we have to deal with

2:53

this situations, that issuppose you have a magnetic core of this kind, ok. And it has

3:18

got a thickness, like this in 3 dimension I am trying to draw, ok andit

3:38

will be like this. So, this is called it it is a made of soft iron and I have drawn it

3:50

right now as a solid iron block. We will see what is to be donebecause solid irons are

3:58

not used. Butthis is the structure of the iron andover

4:02

which there will be coils wound like this, ok. When there is a single coil and there

4:25

is a core like this, core material then if this coil carries current it will produce

4:37

flux inside the core. So, we start with magnetic circuit, ok. We

4:43

just review that because that will be essential in understanding the. ah

4:53

. Magnetic circuit

5:08

because there is a magnetic material, there will be coils wound over it and the coils

5:14

are supposed to carry current therefore, they are going to produce flux in the core. And

5:20

we know thatifthis is the direction of the current, suppose DC current first then the

5:29

direction of the current will be like this in the coil, I. Suppose we have connected

5:36

DC source this is the current. Then what happens, in the core there will be a flux produced

5:45

phi. Deduction of the flux will be as you knowyou wrap your fingers around the coils

5:59

and thumb will give you the direction of the flux produced.

6:05

Of course, if it is a constant DC current whatever flux will be produced inside the

6:09

core that too will have constant values. And how to estimate that flux? You know we apply

6:18

the ampere circuital law to find out the flux produced in the core. For example, you seeif

6:28

if I draw the sectional view of the core, like this, then if you draw the sectional

6:50

view the conductors can be shown to be like this, this is the coil sections.

7:04

How many coils sections you will see? As is the number of turns of this one. And the direction

7:11

of the current as showncan beshown by cross and dot like this this will be cross current,

7:22

cross and these will be dot, is it not. Then,the fluxinside the core what do we do

7:35

is we take a mean path of the flux which I am showing by dotted lines. This is the flux,

7:55

and this red one is the length of the mean path, length of mean path of the flux flux

8:15

that length let me call l. Ifthese are N then ampere circuital laws says that integral H

8:28

dot dl over a closed path is equal to current enclosed, is it. But in this casethe direction

8:48

of H and l are same. Therefore, what will come out to be H into

8:57

l that dot product because the direction of H and l as I move they are same, direction

9:05

of H, direction of B, direction of phi they are all same and also length is like that,

9:12

H dot dl means H into l should be equal to the current enclosed. How much current is

9:19

enclosed by this path? N into I, N into I. We know this, so I will not spend much of

9:26

this time So, this is NI by l. Its unit is ampere turns

9:33

per meter this will be the case. Once I know H then I will calculate B, B will be equal

9:44

to mu 0 mu r into H, where mu are is called the relative permeability of the core and

9:57

if the relationship between B and H is linear, then mu r is a constant value andso this will

10:06

be equal to mu 0 mu r and for H I can write NI by l.

10:17

Then thethen I go here, then the flux produced which is in vapor will be equal to B into

10:28

the cross sectional area A. What is this A? A is this cross sectional area that is this,

10:40

this, this, this, through which flux will be flowing. So, this is A, ok.

10:49

So, this cross sectional area is perpendicular to the flux at any sections therefore,flux

10:56

in vapor will be B into A, and B already I have calculated, so I substitute that mu 0

11:06

mu r NI by l, this is H into area. Now, if you seethis this can be written as NI I am

11:26

sorry, if you see this it will be NI and bring all the other things in the denominator which

11:47

will become 1 by mu 0 mu r l by A. Why I have written in this fashion is this,

12:03

that this is the cause I can identify this, this is the cause and phi is the effect, is

12:22

it. I have supplied with mmf and this magnetic circuit returns c way flux phi. And how to

12:33

calculate that flux? mmf, this is called mmf, and you this is called reluctance. And that

12:47

is why we name magnetic circuit. In case of electrical circuit, I is equal

12:52

to EMF by resistance, and if you recall EMF is EMF voltage resistance is rho l by A. So,

13:06

there is a striking similarity and that is why it is called reluctance. Reluctancelimits

13:14

the value of the flux when you apply an mmf. Although, the the mmf and the flux in electrical

13:24

circuit as you know the circuit is like this resistance and this is your EMF say E E by

13:35

R. And this is the current, but in magnetic circuit this mmf and this flux wherever it

13:42

is flowing they are totally decoupled, I mean it is not that flux is in the conductor.

13:48

But, nonethelessthis equation prompts us tosimplify the matter and say that, asso far as calculation

13:59

of mmf is concerned you do it like this NI and connect it by a relzctance which is shown

14:07

by a curly letter R and here you show the flux. Although, in thisdiagram I show there

14:16

as if connected, but they are not in practice, but only prompted by thisrelationship corresponding

14:23

in the existing in the electrical circuit, it is better, that is why it is called magnetic

14:28

circuit. So, if mmf is known. I will first calculate,

14:32

what is the reluctance. Reluctance of the magnetic circuit per depends upon its geometry,

14:38

what is the length, what is the cross sectional area, cross sectional area is this one of

14:45

this, this is the cross sectional area then you calculate H and I by l, and then multiply

14:53

it withmu 0 mu r to get B, then multiply with a and get that one.

15:01

Therefore, in a simpleexcitation with DC current this value of the flux whatever you will get,

15:09

if you divide the mmf with reluctance that two will be constant and its direction will

15:15

be also fixed in this case it is clockwise, ok.

15:22

The reverse problem is also very simple. In that case I will say that I want to create

15:31

a certain amount of flux what should be the current necessary. So, I will calculate reluctance,

15:41

reluctance into flux will give me NI and if I know the number of turns I will simply divide

15:47

that NI with m to get the current necessary. Anyway, these areknown stuff andwe have a

15:57

magnetic circuit like this, ok. And I will presume that you know about it, so no question

16:03

of further telling about it . Now, we will go to next page, next page ah.

16:13

l thatkeyboard is useful. Let us go to next page.

16:24

Now, I will tell you that what happens if the same magnetic circuit that isthis one,

16:38

this point you listen very carefully and this is the most interesting thing, sorry, I am

17:05

sorry.Let me try to draw another thing here, that is the core I am drawing you must understand.

17:23

Why it is getting circle, anyway hm. So, suppose this is the core of the material

17:47

let me draw slowly, ok. Andsuppose you havethe let us consider a single coil same magnetic

18:01

circuit with N turns, but this time what I will do is this I will connect it to an AC

18:16

source this is AC source of known voltage.

18:25

For example, V 1 is equal to root 2 I am sorry will write it like this v 1 t is equal to

18:47

root 2 V 1, some say sin omega t or cos omega t I will write it applied voltage to this

18:59

coil. Now, if you pass a sinusoidal voltage across the coil, in case of DC circuit magnetic

19:10

circuit what I was telling when the current is constant then NI you calculate mmf divide

19:18

it by reluctance get the flux. But in AC circuit AC magnetic circuit the coil is connected

19:27

across a AC supply voltage of known frequency, rms value V 1 and supply frequency is f.

19:40

Then what I am telling, first I will tell this statement the flux in the core gets fixed

19:50

I mean no question of once the supply voltage and rms value is known, I mean we we do not

20:01

start telling that I will first calculate current, then calculate mmf, thendivide that

20:07

mmf with reluctance to get the flux, not like that; it will be the moment you apply a known

20:18

rms voltage at certain frequency f where omega equal to 2 phi f and AC voltage across the

20:25

coil. The level of flux which will be produced which

20:32

will be also time varying it is expected flux gets fixed. Now, what is the reason for that?

20:45

Reason for that is it is expected whatever current it draws that will be also sinusoidal

20:54

varying, because after all it is some sort of coil or inductance we have connected across

21:00

an AC supply, some alternating current it will draw andsince current value and magnitude

21:11

is changing with time the this phi 2 will be time dependent, sometimes it will be flowing

21:23

to clockwise sometimes in the anticlockwise direction sometimes it will be 0 when the

21:29

instantaneous value of the current will be 0 and so on. But the moment an alternating

21:39

flux is created inside the core of the coil, inside the core of this magnetic circuit between

21:52

these two points they are appears an AC induced voltage.

22:00

Suppose the number of turns of this coil is N or say N 1 single coil l 1. Then according

22:08

to Faraday if there is a coil ifthere is a time varying flux in the coil

22:24

then this coil itself become a seat of EMF. The

22:35

value of instantaneous value of which is some minus N 1 d phi d t about that sign it is

22:41

not necessarily so important, but what I am telling this is the induced voltage the flux

22:49

linking the coil is chaining with time and therefore, there will be induced voltage across

22:56

this coil. In this case this flux is created by the current

23:01

carried by the coil itself, but it does not matter, Faraday says, if there is a change

23:08

of flux rate of change of flux exists linking a coil it is time bearing then between these

23:22

two points it will become a seat of EMF. Negative sign is the Langer's law it tells that the

23:30

polarity of this induced voltage will be such that it will try to oppose the very cause

23:37

for which it is due. For example, this coil can be modeled as here

23:43

is your AC supply V 1 t I have applied. Then what I am telling across this coil if I neglect

23:55

the resistance of the coil there appears another source here and that induced voltage is E

24:05

1, and the polarity of this voltage will be such that if this side is d phi dt is positive

24:13

then it will try to oppose the cause, so its polarity will be like this, ok. Or in other

24:25

words what I am telling, so these these these thing can be now be modeled like these applied

24:33

voltage and there is another induced EMF. In case ofDC magnetic circuit DC 1 will not

24:46

be there, there is applied voltage which is constant. Of course, current will be limited

24:52

by the resistance of the circuit V by r that is why current gets fixed I. But here what

25:03

I am telling the induced voltage in the coil will be same as the applied voltage, only

25:14

thing about the polarity its polarity will be such that it will try to oppose the cause

25:22

very cause that is the flux it will try to oppose it. What was the reason for flux existing

25:30

and increasing? This current it was increasing in the positive direction. So, it will try

25:36

to limit reduce that value of the current that was the reason.

25:44

Anyway, after this I can say that in this loop k V l equation is to be satisfied. Therefore,

25:55

applied rms voltage must be equal tothe rms voltage of V 1 what else, is it. Now, you

26:06

see this flux will be some phi max, say let us forget about this cos omega d sin suppose

26:21

I start with these one phi max equal to sin omega t.

26:25

Why I am assuming this? Because the circuit cannot, but draw sinusoidally varying current

26:32

let call phi is equal to phi max sin omega t. If that be the case then the rms value

26:39

of the then the induced voltage in the coil E 1 will be equal to N 1 d phi 1 dt, ok.

26:52

If you differentiate these this will become equal to N 1 phi max omega sum cos omega t.

27:06

This will the value of the induced voltage, is it. So, what will be the rms value of that

27:12

voltage? It will be the peak value of the voltage phi max, omega by root 2. For omega

27:26

if you substitute 2 phi f, so it will become root 2 phi f phi max into N 1.

27:40

See I am not so much bothered about this minus 1, I should not struggle, my intention here

27:46

is to calculate what is the rms value of the induced voltage, ok. Differentiate it, peak

27:52

value you get divide it by root 2 and that will give you rms voltage.

27:58

What I am telling is in the circuit k V l equation must be satisfied or is vanishingly

28:05

small. So, applied rms voltage must be equal to the induced rms voltage it cannot be other

28:14

than that. Therefore, if the applied rms voltage is V 1 it must be equal to root 2 phi f phi

28:30

max into N 1 is it it has to be f nothing other than that.

28:40

So, what I have told you that in case of AC E same magnetic circuit which I considered

28:49

with DC excitation, if you connect it to an external voltage source which is alternating

28:55

in nature sinusoidally and the rms value of that applied voltage is known current whatever

29:07

flows has to be sinusoidal therefore, phi created inside the core of this magnetic material

29:16

2 will be time dependent and vary sinusoidally. And if this flux vary sinusoidally then Faraday

29:27

tells us that across this two points this two points there will be induced voltage.

29:38

What is the magnitude of this induced voltage rms value? That magnitude of this rms voltage

29:44

is root 2 phi f phi max into N 1. Applied rms voltage is known V 1, induced rms voltage

29:54

is known capital E 1, and these two must be same because k V l is to be satisfied in the

30:04

primary. If that be the case in this equation what are the things I know, V 1 is known,

30:14

supply frequency is known, N 1 is known number of turns, and your phi max is equal to V 1

30:26

by root 2 phi f into N 1. This is the crucial thing.

30:33

As I told you see mind you in case of alternating magnetic circuit if you apply an AC voltage

30:45

the level of flux phi max is decided, decided by whom? By the supply voltage rms value by

30:59

the supply frequency and number of turns. So, is it not? Something different from DC

31:07

circuit; DC circuit you apply some known current, DC current in the circuit calculate mmf divide

31:15

by reluctance, get the flux. But here oh it is somewhat interesting.

31:27

The moment you connectan AC voltage V 1 and f I can tell you the flux is sinusoidally

31:37

varying. What is the maximum value of that flux? It is fixed it is

31:49

this one. Therefore,this phi max how much will be produced inside the core is decided.

31:54

I do not have any control over it. In fact, I will go a step ahead I will tell you.

32:03

If this core material it has got a permeability of mu or one you replace this core material

32:15

with another magnetic material having relative permeability mu r 2 then also phi max is V

32:26

1 by these one. So, no matter what is the kind of magnetic material it is good magnetic

32:36

material, back bad magnetic material, the moment supply rms voltage and supply frequency

32:44

are known phi max in the core is decided. A very crucial point to go ahead with the

32:56

concept of transformer. We will continue with that.

33:00

Thank you.

More transcripts